Validation of a high-performance liquid chromatographic assay method for pharmacokinetic evaluation of busulfan

Jean R. Heggie, Mark Wu, Robbin B. Burns, Carol S. Ng, Henry C. Fung, Gregory Knight, Michael J. Barnett, John J. Spinelli, Leanne Embree

Research output: Contribution to journalArticlepeer-review

35 Scopus citations

Abstract

The development and validation of a high-performance liquid chromatographic (HPLC) assay for determination of busulfan concentrations in human plasma for pharmacokinetic studies is described. Plasma samples containing busulfan and 1,6-bis(methanesulfonyloxy)hexane, and internal standard, were prepared by derivatization with sodium diethyldithiocarbamate (DDTC) followed by addition of methanol and extraction with ethyl acetate. The extract was dried under nitrogen and the samples reconstituted with 100 μl of methanol prior to HPLC determination. Chromatography was accomplished using a Waters NovaPak octadecylsilyl (ODS) (150x3.9 mm I.D.) analytical column, NovaPak ODS guard column, and mobile phase of methanol-water (80:20, v/v) at a flow-rate of 0.8 ml/min with UV detection at 251 nm. The limit of detection was 0.0200 μg/ml (signal-to-noise ratio of 6) with a limit of quantitation (LOQ) of 0.0600 μg/ml for busulfan in plasma. Calibration curves were linear from 0.0600 to 3.00 μg/ml in plasma (500 μg) using a 1/y weighting scheme. Precision of the assay, as represented by C.V. of the observed peak area ratio values, ranged from 4.41 to 13.5% (13.5% at LOQ). No day-to-day variability was observed in predicted concentration values and the bias was low for all concentrations evaluated (bias: 0 to 4.76%; LOQ: 2.91%). The mean derivatization and extraction yield observed for busulfan in plasma at 0.200, 1.20 and 2.00 μg/ml was 98.5% (range 93.4 to 107%). Plasma samples containing potential busulfan metabolites and co-administered drugs, which may be present in clinical samples, provided no response indicating this assay procedure is selective for busulfan. This method was used to analyze plasma concentrations following administration of a 1 mg/kg oral busulfan dose.

Original languageEnglish
Pages (from-to)437-444
Number of pages8
JournalJournal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
Volume692
Issue number2
DOIs
StatePublished - May 9 1997

Keywords

  • Busulfan/blood
  • Chromatography, High Pressure Liquid/methods
  • Humans
  • Mass Spectrometry/methods
  • Reference Standards
  • Reproducibility of Results
  • Sensitivity and Specificity