Skip to main navigation Skip to search Skip to main content

Intraoperative identification of esophageal sentinel lymph nodes with near-infrared fluorescence imaging

  • Cherie P Parungo
  • , Shunsuke Ohnishi
  • , Sang-Wook Kim
  • , Sunjee Kim
  • , Rita G Laurence
  • , Edward G Soltesz
  • , Frederick Y Chen
  • , Yolonda L Colson
  • , Lawrence H Cohn
  • , Moungi G Bawendi
  • , John V Frangioni

Research output: Contribution to journalArticlepeer-review

180 Scopus citations

Abstract

OBJECTIVE: In esophageal cancer, selective removal of involved lymph nodes could improve survival and limit complications from extended lymphadenectomy. Mapping with vital blue dyes or technetium Tc-99m often fails to identify intrathoracic sentinel lymph nodes. Our purpose was to develop an intraoperative method for identifying sentinel lymph nodes of the esophagus with high-sensitivity near-infrared fluorescence imaging.

METHODS: Six Yorkshire pigs underwent thoracotomy and received submucosal, esophageal injection of quantum dots, a novel near-infrared fluorescent lymph tracer designed for retention in sentinel lymph nodes. Six additional pigs underwent thoracotomy and received submucosal esophageal injection of CW800 conjugated to human serum albumin, another novel lymph tracer designed for uptake into distant lymph nodes. Finally, 6 pigs received submucosal injection of the fluorophore-conjugated albumin with an endoscopic needle through an esophagascope. These lymph tracers fluoresce in the near-infrared, permitting visualization of migration to sentinel lymph nodes with a custom intraoperative imaging system.

RESULTS: Injection of the near-infrared fluorescent lymph tracers into the esophagus revealed communicating lymph nodes within 5 minutes of injection. In all 6 pigs that received quantum dot injection, only a single sentinel lymph node was identified. Among pigs that received fluorophore-conjugated albumin injection, in 5 of 12 a single sentinel lymph node was revealed, but in 7 of 12 two sentinel lymph nodes were identified. There was no dominant pattern in the appearance of the sentinel lymph nodes either cranial or caudal to the injection site.

CONCLUSION: Near-infrared fluorescence imaging of sentinel lymph nodes is a novel and reliable intraoperative technique with the power to assist with identification and resection of esophageal sentinel lymph nodes.

Original languageEnglish
Pages (from-to)844-850
Number of pages7
JournalJournal of Thoracic and Cardiovascular Surgery
Volume129
Issue number4
DOIs
StatePublished - Apr 2005

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Animals
  • Esophagoscopy
  • Esophagus/pathology
  • Fluorescent Dyes
  • Intraoperative Care
  • Lymph Nodes/pathology
  • Male
  • Quantum Dots
  • Reproducibility of Results
  • Sentinel Lymph Node Biopsy
  • Serum Albumin
  • Spectroscopy, Near-Infrared/methods
  • Swine
  • Thoracotomy
  • Time Factors

Fingerprint

Dive into the research topics of 'Intraoperative identification of esophageal sentinel lymph nodes with near-infrared fluorescence imaging'. Together they form a unique fingerprint.

Cite this