TY - JOUR
T1 - Dosimetric evaluation of integrated IMRT treatment of the chest wall and supraclavicular region for breast cancer after modified radical mastectomy
AU - Yang, Bo
AU - Wei, Xian ding
AU - Zhao, Yu tian
AU - Ma, Chang Ming
PY - 2014
Y1 - 2014
N2 - To investigate the dosimetric characteristics of irradiation of the chest wall and supraclavicular region as an integrated volume with intensity-modulated radiation therapy (IMRT) after modified radical mastectomy. This study included 246 patients who received modified radical mastectomy. The patients were scanned with computed tomography, and the chest wall (with or without the internal mammary lymph nodes) and supraclavicular region were delineated. For 143 patients, the chest wall and supraclavicular region were combined as an integrated planning volume and treated with IMRT. For 103 patients, conventional treatments were employed with 2 tangential fields for the chest wall, abutting a mixed field of 6-MV x-rays (16Gy) and 9-MeV electrons (34Gy) for the upper supraclavicular region. The common prescription dose was 50Gy/25Fx/5W to 90% of the target volume. The dosimetric characteristics of the chest wall, the supraclavicular region, and normal organs were compared. For the chest wall target, compared with conventional treatments, the integrated IMRT plans lowered the maximum dose, increased the minimum dose, and resulted in better conformity and uniformity of the target volume. There was an increase in minimum, average, and 95% prescription dose for the integrated IMRT plans in the supraclavicular region, and conformity and uniformity were improved. The V30 of the ipsilateral lung and V10, V30, and mean dose of the heart on the integrated IMRT plans were lower than those of the conventional plans. The V5 and V10 of the ipsilateral lung and V5 of the heart were higher on the integrated IMRT plans (p < 0.05) than on conventional plans. Without an increase in the radiation dose to organs at risk, the integrated IMRT treatment plans improved the dose distribution of the supraclavicular region and showed better dose conformity and uniformity of the integrated target volume of the chest wall and supraclavicular region.
AB - To investigate the dosimetric characteristics of irradiation of the chest wall and supraclavicular region as an integrated volume with intensity-modulated radiation therapy (IMRT) after modified radical mastectomy. This study included 246 patients who received modified radical mastectomy. The patients were scanned with computed tomography, and the chest wall (with or without the internal mammary lymph nodes) and supraclavicular region were delineated. For 143 patients, the chest wall and supraclavicular region were combined as an integrated planning volume and treated with IMRT. For 103 patients, conventional treatments were employed with 2 tangential fields for the chest wall, abutting a mixed field of 6-MV x-rays (16Gy) and 9-MeV electrons (34Gy) for the upper supraclavicular region. The common prescription dose was 50Gy/25Fx/5W to 90% of the target volume. The dosimetric characteristics of the chest wall, the supraclavicular region, and normal organs were compared. For the chest wall target, compared with conventional treatments, the integrated IMRT plans lowered the maximum dose, increased the minimum dose, and resulted in better conformity and uniformity of the target volume. There was an increase in minimum, average, and 95% prescription dose for the integrated IMRT plans in the supraclavicular region, and conformity and uniformity were improved. The V30 of the ipsilateral lung and V10, V30, and mean dose of the heart on the integrated IMRT plans were lower than those of the conventional plans. The V5 and V10 of the ipsilateral lung and V5 of the heart were higher on the integrated IMRT plans (p < 0.05) than on conventional plans. Without an increase in the radiation dose to organs at risk, the integrated IMRT treatment plans improved the dose distribution of the supraclavicular region and showed better dose conformity and uniformity of the integrated target volume of the chest wall and supraclavicular region.
KW - Breast cancer
KW - Dosimetry
KW - IMRT
KW - Radiotherapy
UR - http://www.scopus.com/inward/record.url?scp=84899929456&partnerID=8YFLogxK
UR - https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=purepublist2023&SrcAuth=WosAPI&KeyUT=WOS:000336465900012&DestLinkType=FullRecord&DestApp=WOS
U2 - 10.1016/j.meddos.2013.12.008
DO - 10.1016/j.meddos.2013.12.008
M3 - Article
C2 - 24503002
SN - 0958-3947
VL - 39
SP - 185
EP - 189
JO - Medical Dosimetry
JF - Medical Dosimetry
IS - 2
ER -